[Top] [Prev] [Next] [Contents]  [Index]
 
 EXECD Messages
EXECD messages pertain to the execution of local clients. If you are looking for a message that refers to the EXECD module but does not appear here, refer to "Messages Common to All Modules".
BADCMD, invalid command: command
- Severity:
 - Error
 
- Explanation:
 - The EXEC daemon does not recognize the specified command, 
usually a local client command.
 
- User Action:
 - Check the System Administrator's Guide for UNIX Systems or the 
client man page to determine the correct command for the desired local client.
 
BADERRPORT, invalid error port number in request
- Severity:
 - Error
 
- Explanation:
 - The X server has detected an internal error.
 
- User Action:
 - If you encounter this message, please contact NCD Technical 
Support.
 
BADLICENSE, terminal not licensed for: feature
- Severity:
 - Error
 
- Explanation:
 - The terminal does not have a license for the specified feature, 
such as DPS. 
 
- User Action:
 - Contact NCD to obtain a valid license for the desired feature and 
enter it in the terminal's remote configuration file, NVRAM, or license.dat file.
 
BADMODDIR, bad modules directory: dir
- Severity:
 - Error
 
- Explanation:
 - The X server was unable to load modules from the configured 
directory.
 
- User Action:
 - Make sure that the modules are in the correct location and 
accessible.
 
BADPARAMS, invalid parameters given for: client
- Severity:
 - Error
 
- Explanation:
 - The specified local client does not recognize the command-line 
options it received through the EXEC daemon.
 
- User Action:
 - Verify that the command-line options are correct for the 
specified client.
 
BADPORT, refused request from nnn.nnn.nnn.nnn on bad port n
- Severity:
 - Error
 
- Explanation:
 - The EXEC daemon has received a request for connection from 
the specified host. The EXEC daemon is refusing the request because the 
request did not originate from a privileged TCP port on the host. Specifically, 
the requesting TCP port number is equal to or greater than 1024.
 
- User Action:
 - Verify the host system is using the correct TCP port.
 
DISABLEDCMD, command has been disabled:command
- Severity:
 - Error
 
- Explanation:
 - Command cannot be executed because it has been configured as 
disabled.
 
- User Action:
 - Remove command from the exec-disabled-commands remote 
configuration parameter.
 
LOADCMD, error loading command:command
- Severity:
 - Error
 
- Explanation:
 - The X server is unable to load a module needed to run the 
command.
 
- User Action:
 - Make sure that the modules are present and in the correct 
location.
 
LOADDISABLED, loading of module module has been disabled
- Severity:
 - Error
 
- Explanation:
 - The module has been configured to be disabled.
 
- User Action:
 - Change the load policy for the module in the modules-load-
policy remote configuration parameter.
 
LONGCMD, command string too long
- Severity:
 - Error
 
- Explanation:
 - The command that has been entered exceeds the limit of 512 
characters. 
 
- User Action:
 - Re-enter the command, limiting the entry to 512 characters.
 
LONGUSER, user name too long
- Severity:
 - Error
 
- Explanation:
 - The user name that has been entered is too long. 
 
- User Action:
 - Re-enter the user name, limiting the entry to 16 characters.
 
NOERRCONN, unable to connect to error socket: message
- Severity:
 - Error
 
- Explanation:
 - The network connection has failed.
 
- User Action:
 - Verify that the host is operational, that it is communicating on 
the network, and that the network is working.
 
NOERRPORT, unable to read port number from request
- Severity:
 - Error
 
- Explanation:
 - The X server has detected an internal error.
 
- User Action:
 - If you encounter this message, please contact NCD Technical 
Support.
 
NONIPERRPORT, error port given on non-IP connection
- Severity:
 - Error
 
- Explanation:
 - The X server has specified a port number when communicating 
across a DECnet network. 
 
- User Action:
 - If you encounter this message, please contact NCD Technical 
Support.
 
NORESPORT, no reserved ports available
- Severity:
 - Error
 
- Explanation:
 - The X server has detected an internal error.
 
- User Action:
 - If you encounter this message, please contact NCD Technical 
Support.
 
OPENMODFAIL, unable to open module module
- Severity:
 - Error
 
- Explanation:
 - The X server cannot find module.
 
- User Action:
 - Make sure that the module is in the modules directory.
 
PROCLIM, too many copies already running: client
- Severity:
 - Error
 
- Explanation:
 - The user has requested a local client when the maximum 
number of the client's processes already exist.
 
- User Action:
 - Use an existing client process, or close one of the existing client 
processes and open a new one.
 
START, running command: command
- Severity:
 - Information
 
- Explanation:
 - The EXECD module has started the specified command as 
requested.
 
- User Action:
 - None
 
UNKNOWNERR, unknown error for: client
- Severity:
 - Error
 
- Explanation:
 - The specified local client has failed with an unknown error 
code.
 
- User Action:
 - If you encounter this message, please contact NCD Technical 
Support.
 
 
[Top] [Prev] [Next] [Contents]  [Index]
Send comments, suggestions, or questions about this document to the NCD Technical Publications Department by Internet e-mail.  Write to us at 
techpubs@ncd.com.
Copyright © 1997, NCD Inc.   All rights